LinkedIn Instagram Facebook YouTube WhatsApp
Industrial Flow Measurement

Electromagnetic Flowmeter for Accurate Liquid Flow Measurement

Measure conductive liquids with dependable flow data. Metazone Engineers electromagnetic flowmeters feature a full-bore design with no moving parts for stable readings and low maintenance.

Suitable for water, wastewater, chemicals and slurry applications, with configurable options to match your process requirements.

Download Brochure
No moving parts
±0.5% standard accuracy
Bidirectional measurement
RELIABLE MEASUREMENTFor conductive liquids
Metazone Engineers electromagnetic flowmeter
INDUSTRIAL-READY DESIGNIntegral or remote display

Consistent readings. Less routine maintenance.

Engineered to measure conductive liquids without obstructing the pipe's flow path.

Product Overview

Dependable measurement for everyday plant operations

Metazone Engineers electromagnetic flowmeters measure conductive liquids in pipelines where operators need reliable readings for process monitoring, water management and billing.

The meter works on Faraday’s Law of Electromagnetic Induction. With no moving parts in the flow path, it helps keep routine maintenance low. Its full-bore design also lets liquid pass through without an obstruction from the meter itself.

  • Suitable for water, wastewater, chemicals and slurry
  • Multiple lining and electrode options according to fluid type
  • 4–20 mA, RS485, Pulse and Profibus output options
  • Integral or remote transmitter configurations
Industrial flow meter installed in a modern plant
Built for Industrial Applications

Reliable flow data where it matters

Support process monitoring, water management and liquid-flow measurement with a meter configured around your application conditions.

Water & wastewaterIndustrial processesLiquid flow monitoring
Technical Data

Technical Specifications

Review the standard specifications below. Final configuration depends on the liquid, line size and operating conditions.

Need a specific configuration?

Share your pipe size, liquid type, temperature and pressure so our team can help identify a suitable configuration.

ParameterDetails
MediaConductive liquids
ConductivityMore than 15 µS/cm
Nominal diameter15 to 600 mm
Working pressure10, 16, 25 kg/cm²
Working temperatureUp to 80°C for PTFE lining; up to 80°C for rubber lining (confirm application conditions)
Accuracy±0.5% of measured value
Repeatability±0.2% of span
Electrode materialSS 316L (standard), Hastelloy C, Platinum, Titanium, Tantalum
Sensor liningRubber (standard), PTFE
Measuring tubeSS 304 (standard)
Sensor housingCarbon Steel (standard)
End connectionFlange, Wafer; flange standard
Display versionIntegral or Remote
DisplayGraphic display or 16×2 line display
Display unitsm³, litre, gallon, ft³
Output4–20 mA (standard), RS485, Pulse, Profibus
Power supply24–48 V DC, 220–240 V AC, or solar-powered option
Sensor protectionIP65 standard; IP67 optional for remote-type flow tube
Transmitter protectionIP65 / IP66
Remote cable length5 m standard
InstallationInline flanged type
Working Principle

How does an electromagnetic flowmeter work?

The flowmeter creates a magnetic field inside the pipe. When a conductive liquid passes through it, a small voltage is produced. Sensors measure this voltage, and the transmitter converts it into a flow reading.

Material Selection

Choose the right lining and electrode

Material selection should match the liquid and its operating conditions. Contact our team if you need help selecting a combination.

Sensor Lining

Rubber: A common choice for water, wastewater and slurry. Confirm temperature and chemical compatibility for the actual application.

PTFE: Offers resistance to many chemicals. Confirm compatibility and the allowable operating temperature before selection.

Electrode Material

SS 316L: Standard choice for many water applications.

Hastelloy C, Titanium, Tantalum or Platinum: Options for selected acids, chemicals and demanding fluids, subject to compatibility review.

Chemical-use configurations can be requested.

Applications

Where can electromagnetic flowmeters be used?

From water treatment to heavy industry, the right meter configuration helps teams keep track of conductive liquid flows across the plant.

Water supply & treatment
Sewage & wastewater
Chemical & pharmaceutical
Food, dairy & beverage
Paper, pulp & textile
Power plants
Irrigation & agriculture
Mining & slurry lines
Steel & cement plants
Key Features & Benefits

Practical performance for everyday operation

A straightforward flow measurement solution with configuration choices for different industrial requirements.

01 / ACCURACY

High Accuracy

Standard accuracy of ±0.5% of measured value. ±0.2% option available on request.

02 / DESIGN

No Moving Parts

Helps reduce mechanical wear and routine maintenance requirements.

03 / FLOW PATH

Full-Bore Design

The open flow tube helps avoid pressure drop caused by an obstruction in the flow path.

04 / FLEXIBILITY

Wide Size Range

Nominal diameters from 15 mm to 600 mm in the supplied product specification; confirm project-specific sizes with our team.

05 / DISPLAY

Clear Readout

Choose a graphic display or a 16×2 line display according to requirements.

06 / CONNECTIVITY

Flexible Outputs

4–20 mA, RS485, Pulse and Profibus options for system integration.

Configuration Options

Integral and remote versions

Integral Type

The display is mounted directly on the flow tube. A compact arrangement that can be convenient where the meter is readily accessible.

Remote Type

The display is located away from the flow tube using a cable (5 m standard). Useful for locations that are difficult to reach, hot, wet or crowded.

Why Metazone Engineers?

Support from selection to service

ISO 9001:2015Certified company
Strong BuildDesigned for a long working life
Custom OptionsSizes, linings and electrodes
Technical SupportSelection, installation and after-sales support
Value & DeliveryCompetitive pricing and on-time delivery
Get Started

Find the right electromagnetic flowmeter for your process

Share your pipe size, liquid type, temperature and pressure. Our team can help review the requirements and provide a quotation.

Contact Us
Scroll to Top