Liquid Flow
Clear liquid enters the in-line flow tube and engages the vaned rotor positioned in the flow path.
Measure clear-liquid flow with the METAZONE Series T-TFM Turbine Flow Meter. Designed for industrial process lines, it converts rotor movement into electrical signals for flow-rate indication and totalised flow measurement.
The T-TFM series uses a vaned rotor placed in the flow path. As clear liquid passes through the meter, the rotor turns and a Hall-effect sensor detects its motion, producing a pulsating electrical signal related to flow.
Designed for clear-liquid flow measurement in demanding process environments. The T-TFM series can be applied to oil and gas operations including water injection, separator systems, disposal wells and chemical injection lines.
Review the standard specifications of the METAZONE T-TFM Turbine Flow Meter. Special requirements and configurations can be discussed with our team.
| Parameter | Details |
|---|---|
| Meter Type | Integral mounted (standard); remote mounted (on request) |
| Media | Clear liquid |
| Signal Output | 4–20 mA, RS485 and pulse with adjustable count |
| Display | 4-digit flow rate and 8-digit totalised flow |
| Power Supply | 90–260 V AC, 50 Hz; 24 V DC and 12 V DC on request |
| Line Size | 15 NB to 65 NB; consult factory for sizes above 65 NB |
| Accuracy | ±1% of full scale (for 20–100% flow) |
| Repeatability | ±1% of reading |
| Linearity | ±1% |
| Ambient Temperature | 0 to 100 °C |
| Operating Pressure | Up to 10 kg/cm²; consult factory for other requirements |
| Transmitter Enclosure | Die-cast aluminium, IP66; flow tube, IP68 |
| Process Connection | ASA 150 flanged, as per Table 16.5 |
| Rotor | Magnetic-coated Nylon 66 |
| Pressure Drop | Approx. 0.28 kg/cm² maximum |
| Flange Material | CS / MS / SS |
| Pipe Material | MS / SS304 / SS316 |
| Mounting | In-line; vertical or horizontal |
| Response Time | Less than 100 ms |
| Viscosity | 100 cP maximum (as stated in catalogue) |
The flowing liquid engages a vaned rotor inside the meter body. Rotor speed follows the flow rate, while a Hall-effect sensor detects rotor movement and converts it into pulsating electrical signals. Signal frequency is proportional to flow rate, and pulse summation relates to total flow.
Clear liquid enters the in-line flow tube and engages the vaned rotor positioned in the flow path.
The rotor rotates as liquid passes through the meter. Its rotational frequency changes in proportion to the flow rate.
The Hall-effect sensor detects rotor motion and produces electrical pulses for flow-rate and total-flow measurement.
The catalogue specifies in-line installation in either vertical or horizontal orientation. Flange and pipe material options are available to suit the specified construction requirements.
Flanges: CS, MS or SS options
Pipe: MS, SS304 or SS316 options
Process connection: ASA 150 flanged
Mounting: In-line, vertical or horizontal
The product catalogue identifies oil and gas applications including the following process duties.
*Natural gas pipeline is listed in the catalogue application list. The meter media specification separately states clear liquid; confirm media suitability with the factory before selection.
A turbine-based measurement approach with configurable mounting and signal options for industrial clear-liquid applications.
Specified accuracy of ±1% of full scale over 20–100% of flow.
Local LCD display provides flow-rate and totalised-flow information.
4–20 mA, RS485 and pulse output options support integration needs.
Select the mounting arrangement according to the installation layout and display access requirements.
Integral mounting is the standard configuration, with the transmitter and display mounted on the meter assembly.
Remote mounting is available on request for installations where a separate display location is preferred.
Get assistance in reviewing process conditions and selecting a suitable Turbine Flow Meter configuration.
Discuss line size, media and operating conditions.
Review mounting, output and power options.
Get product-related technical assistance.
Discuss catalogue and technical details.
Connect with our team for your enquiry.
Share your line size, liquid, power supply and output requirements. Contact Metazone Engineers to discuss the T-TFM series for your application.