Brass
Often used in small water-meter bodies or threaded connections for compatible water applications.
Measure liquid flow or total water usage with a practical mechanical measuring system and an easy-to-read analog register. Designed for suitable water supply, utility, irrigation and industrial applications.
A Mechanical Flowmeter is an instrument used to measure the flow rate or total volume of liquid moving through a pipe. It uses moving mechanical components to sense flow and transfer movement to a dial or counter, allowing the measured quantity to be read locally.
Depending on the meter design, the measuring mechanism may use a turbine, impeller, gears, pistons, discs or vanes. Many mechanical meters provide basic measurement without an external power supply. The exact internal mechanism of the pictured meter should be confirmed against its model documentation.
Review the key product parameters before finalising a meter for your application. Exact values depend on the selected model and its datasheet.
Need a specific configuration?
Share your pipe size, flow range, fluid and operating conditions with our team for model confirmation.
| Parameter | Specification / Status |
|---|---|
| Product Name | Mechanical Flowmeter / Analog Flowmeter |
| Display | Mechanical dial / counter |
| Measured Quantity | Accumulated volume; instantaneous flow indication depends on model |
| Measuring Principle | Model-dependent: turbine, positive displacement, multi-jet, Woltmann, variable area, paddle wheel, etc. |
| Nominal Size | To be confirmed from product datasheet |
| Typical Industry Size Examples | Some turbine / Woltmann meters are available from around DN15 to DN300+; not confirmed for this pictured product |
| Accuracy | Model-dependent; verify stated class and test conditions |
| Repeatability | To be confirmed |
| Turndown Ratio | To be confirmed; depends on measuring principle and model |
| Operating Pressure | To be confirmed from rated pressure and pressure-loss data |
| Operating Temperature | To be confirmed; depends on meter, seals and fluid |
| Body Material | To be confirmed from product datasheet |
| Wetted Parts | To be confirmed for fluid compatibility |
| Connection | Threaded or flanged, depending on model |
| Output | Mechanical register; pulse or 4–20 mA only if a compatible option is provided |
| Power Supply | Not required for basic mechanical indication; electronic add-ons may need power |
| Approvals / Standards | To be confirmed from manufacturer documentation |
Liquid enters the meter and moves an internal component such as a turbine rotor, impeller, piston, disc or gear set, depending on the design. This movement is transferred to a mechanical register, which records the total volume passing through the meter.
In velocity-based meters, rotor speed is related to flow velocity within the calibrated operating range. In positive-displacement meters, chambers measure repeated known volumes. As liquid passes through the meter, the displayed reading increases.
Material selection depends on the liquid, operating conditions and compatibility requirements. The following are common examples across mechanical meter designs, not confirmed materials for the pictured unit.
Often used in small water-meter bodies or threaded connections for compatible water applications.
Used in some larger meter bodies. Protective coatings may help improve corrosion resistance.
Selected for components requiring strength and greater corrosion resistance, subject to fluid compatibility.
Used in selected meter designs where its properties and fluid compatibility are appropriate.
May include engineering plastics, metals or other materials depending on the measuring design.
A transparent cover protects the register, while seals and gaskets help prevent leakage at joints.
Final material selection should always be verified against the manufacturer’s product documentation.
Mechanical meters are used in a range of water and utility applications when the selected model is rated for the service conditions.
*Oil, fuel and process liquids require a meter specifically designed and approved for the relevant fluid. A water meter must not be assumed suitable.
A straightforward measurement approach for applications that benefit from a locally readable mechanical register.
Moving parts detect flow or measure a known volume, depending on the meter principle.
A dial or counter lets operators check the accumulated quantity directly at the installation point.
The mechanical register does not need an external supply for basic indication; optional electronics may need power.
Different measuring principles serve different flow ranges, pipe sizes and liquid conditions.
Threaded and flanged connection options may be available depending on the selected model.
The appropriate meter type can be selected to meet the measurement needs of the application.
A standard mechanical flowmeter displays readings locally through its register. Some models can be equipped with a pulse-output module or compatible remote-reading accessory. Where supported, measurement pulses can be sent to a counter, data logger, PLC or monitoring system.
A 4–20 mA signal generally requires a compatible electronic transmitter or accessory and should not be assumed to be built into a basic mechanical meter. Confirm output type, wiring, power requirements and compatibility before planning integration.
*Only when the selected meter supports a compatible pulse-output accessory. This is an illustrative integration path, not a confirmed feature of the pictured meter.
Share your application details and operating conditions to identify a suitable model.