Wall Mounted Ultrasonic Flow Meter for Accurate Flow Monitoring
Monitor liquid flow with advanced ultrasonic measurement technology. The wall-mounted ultrasonic flow meter uses external transducers to measure liquid flow through a pipe, offering a practical solution for fixed-point industrial flow monitoring without inserting measuring components into the flowing medium.
Reliable Flow Measurement for Industrial Pipelines
The Wall Mounted Ultrasonic Flow Meter is designed for continuous monitoring of liquid flow in industrial pipeline systems. Its electronic transmitter works with a pair of ultrasonic transducers installed externally on the pipe.
By analysing the travel time of ultrasonic signals moving with and against the liquid flow, the instrument determines flow velocity and calculates the corresponding volumetric flow rate.
- External clamp-on transducer arrangement
- Wall-mounted electronic transmitter
- Digital flow indication and monitoring
- Suitable for configured liquid and pipe applications
Designed for Diverse Liquid Flow Applications
Ultrasonic flow measurement can support a wide range of liquid monitoring requirements. Application suitability depends on the liquid, pipe material, pipe condition and selected transducer configuration.
Technical Details & Measurement Parameters
Review the reference configuration parameters for the wall-mounted ultrasonic flow meter. Final specifications should be confirmed against the selected instrument and transducer configuration.
Choose the Right Configuration
Pipe dimensions, wall thickness, pipe material, liquid properties and sensor arrangement are important when selecting an ultrasonic flow measurement system.
Share your pipeline details with our team to discuss a suitable configuration for your application.
Discuss Your Requirement| Product Type | Wall Mounted Ultrasonic Flow Meter |
| Measurement Principle | Transit-Time Ultrasonic Measurement |
| Reference Accuracy | ±1% (reference configuration) |
| Reference Pipe Size | DN15 – DN6000 |
| Transducer Options | S / M / L (reference options) |
| Reference Flow Velocity | ±32 m/s |
| Reference Output | 4–20 mA, OCT, RS485 |
| Communication | MODBUS RTU / RS485 |
| Reference Power Supply | AC 220 V / DC 24 V |
| Power Consumption | Less than 1.5 W (reference) |
| Flow Direction | Bidirectional measurement (reference) |
| Reference Liquid Temperature | Standard: -30°C to 90°C; High-temperature: up to 160°C |
| Pipe Materials | Application-dependent; compatible pipe material and lining must be confirmed |
| Display | Digital display / flow indication |
Note: Values above are sourced from a published reference configuration, not a confirmed Metazone model datasheet. Actual operating limits, sensor range, outputs and accuracy must be verified before ordering.
How Does a Wall Mounted Ultrasonic Flow Meter Work?
The instrument uses the transit-time difference of ultrasonic signals to determine the velocity of liquid moving through a pipe.
Conceptual illustration of external ultrasonic sensor placement
Transit-Time Measurement Technology
A pair of transducers is positioned on the external surface of the pipe. The transducers alternately transmit and receive ultrasonic signals through the pipe wall and liquid.
The signal travelling downstream moves with the liquid flow, while the upstream signal travels against it. The difference between their travel times is used to calculate average liquid velocity.
Ultrasonic pulses are transmitted through the pipe and liquid.
Downstream and upstream signal travel times are compared.
The measured time difference is used to calculate liquid velocity and flow.
The transmitter processes and displays the calculated measurement values.
Where Can Wall Mounted Ultrasonic Flow Meters Be Used?
Suitable applications may include liquid flow monitoring across different industrial sectors, subject to process and installation conditions.
Practical Performance for Everyday Flow Monitoring
A wall-mounted ultrasonic measurement arrangement offers several practical advantages when correctly selected and installed for the pipeline and process conditions.
Ultrasonic Technology
Uses ultrasonic signal transit-time measurement to determine liquid flow velocity.
External Sensor Mounting
Clamp-on transducers are installed on the pipe exterior without projecting into the flow.
Digital Monitoring
Electronic transmitter processes flow signals for digital measurement and indication.
Flow Direction Monitoring
Configured bidirectional systems can determine flow in both directions.
Signal Integration
Configured output and communication interfaces can support industrial monitoring systems.
Flexible Installation
Wall-mounted transmitter and external sensors provide a fixed-point measurement arrangement.
Support from Selection to Service
Get assistance in identifying the measurement requirements, reviewing pipeline conditions and selecting an appropriate ultrasonic flow measurement configuration.
Quality Focus
Attention to product requirements and measurement suitability.
Configuration
Support for reviewing pipe and application parameters.
Technical Support
Assistance with product selection and technical queries.
Product Supply
Product supply aligned with the agreed requirement.
Delivery Support
Coordination for order processing and delivery.
Find the Right Ultrasonic Flow Meter for Your Application
Share your pipeline requirements and discuss a suitable measurement configuration with Metazone Engineers.